Quote:
Originally Posted by R.Mojica View Post
isn't 2300psi oem pressure?
Greenbook specs conversion math is off.

Operation AG14 shows checking injector pop value 14.5 - 16.3 MPa (2062 - 2318 psi). Should be (2103 - 2364 psi), if my calculations are correct.

Operation AG16 shows reconditioning injector pop to 15.2 - 16.3 MPa (1780 - 1920 psi). Should be (2205 - 2364 psi), if my calculations are correct.

Operation AG15 shows leak testing injector to hold 13.5 MPa (1920 psi) ( Should be 1958 psi) for 10 seconds with no drip. I like to test that for longer, and for the nozzle face to not even start to get moist.
__________________
1985 744 gle d24t
1985 745 gle d24t